1 - Top Security anti-scale barrier is delivered palatised, densely packed with a shrink wrap covering to minimise carriage costs.
2 - In order to reduce bulk spikes are not pre-formed into the final configuration prior to package.
3 - Ensure that the curved brackets are located firmly in position allowing for the centre spindle to portrude through 25mm at each end when placed in position.
4 - Splay the spikes into position and interlock into pairs. Threading each pair onto the centre spindle using the double ended flared ferrules to space them apart. Finish both ends of each section with a half ferrule. N.B for fixing above palisade fences a cruved bracket should be used centrally with half ferrules either side.
5 - Position the fully assembled sections, feeding the end of the centre spindle through one of the two holes in the top of the curved bracket.
6 - Complete by crimping the portruding ends of the centre spindle to permanently locate the section in position.
(Due to the dangers involved with the installation of the Top Security anti-scale barrier, it is essential that protective clothing and goggles are worn) |